Skip navigation

Use este identificador para citar ou linkar para este item: https://repositorio.ufpb.br/jspui/handle/123456789/16764
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSiqueira, Alcides da Silva-
dc.date.accessioned2020-02-10T18:13:13Z-
dc.date.available2019-03-08-
dc.date.available2020-02-10T18:13:13Z-
dc.date.issued2019-02-27-
dc.identifier.urihttps://repositorio.ufpb.br/jspui/handle/123456789/16764-
dc.description.abstractAromatic Polycyclic Hydrocarbons are compounds formed by two or more condensed aromatic rings and constituting a group of more than one hundred substances. Sixteen of these are monitored because of increased human exposure, toxicity, and possible carcinogenic and / or mutagenic effects. They are emerging pollutants formed by incomplete combustion that are generated in large quantity and continuously by human activity. The analytical methods used to determine these analytes are time consuming, high solvent consumption and require extraction and / or preconcentration. Soxhlet extraction is recommended and the concentration step of the organic extract is generally done by roto-evaporation or nitrogen flow. In these procedures, evaporative losses occur of more volatile species, such anthracene and phenanthrene. In this context, the solid phase extraction with membrane allied to the fluorescence spectroscopy directly on the membrane shows a sensitive, fast and low cost alternative that, together with the higher order calibration, allows to q uantify these compounds in several matrices. This set of techniques has a limitation for its application in real systems: possible suspended particles in the sample solution are retained in the membrane after the extraction and can compromise the detection of fluorescence by filter effect, making it impossible to apply to matrices that are more complex. Thus, in the present work a methodology was developed for the determination of ANT and FEN in water and soil samples using solid phase extraction in nylon membrane, direct total membrane fluorescence spectroscopy and second order calibration. The strategy used to avoid the interference of particulates retained in the filtration was to perform the detection on the opposite side of the filter. The results showed that the proposed method allows to identify phenanthrene and anthracene, and to quantify phenanthrene in a simple, fast and efficient way in samples of soils and tap water containing the two isomers.pt_BR
dc.description.provenanceSubmitted by Maria Jose Rodrigues Paiva (mariaj.paiva@biblioteca.ufpb.br) on 2020-02-10T18:13:13Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) Arquivototal.pdf: 2453426 bytes, checksum: b7c9a413cc7b4f0bd252cafdb5807861 (MD5)en
dc.description.provenanceMade available in DSpace on 2020-02-10T18:13:13Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) Arquivototal.pdf: 2453426 bytes, checksum: b7c9a413cc7b4f0bd252cafdb5807861 (MD5) Previous issue date: 2019-02-27en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rightsAcesso abertopt_BR
dc.rightsAttribution-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/*
dc.subjectHidrocarbonetos policíclicos aromáticospt_BR
dc.subjectEspectroscopia de fluorescênciapt_BR
dc.subjectExtração em fase sólidapt_BR
dc.subjectMembrana de náilonpt_BR
dc.subjectCalibração de segunda ordempt_BR
dc.subjectPARAFACpt_BR
dc.subjectPolycyclic aromatic hydrocarbonspt_BR
dc.subjectFluorescence spectroscopypt_BR
dc.subjectContinuous phase extractionpt_BR
dc.subjectNylon membranept_BR
dc.subjectSecond order calibrationpt_BR
dc.subjectHidrocarbonetos aromáticospt_BR
dc.subjectEspectroscopiapt_BR
dc.subjectAntraceno - Determinação em água e solopt_BR
dc.subjectFenantreno - Determinação em água e solo.pt_BR
dc.titleMetodologia analítica para determinação de HPAs leves em águas e solos por extração em fase sólida com membrana de náilon, espectrofluorimetria e calibração de segunda ordempt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Fragoso, Wallace Duarte-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2235816844634343pt_BR
dc.contributor.advisor2Almeida, Luciano Farias de-
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/9741649526799543pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/1866006845515049pt_BR
dc.description.resumoOs Hidrocarbonetos Policíclicos Aromáticos são compostos formados por dois ou mais anéis aromáticos condensados e que constituem um grupo de mais de cem substâncias conhecidas. Dezesseis dessas são monitoradas devido à maior exposição humana, toxicidade e seus possíveis efeitos carcinogênicos e/ou mutagênicos em humanos. Eles são poluentes emergentes formados por combustão incompleta, sendo gerados em grande quantidade e de forma contínua pela atividade humana. Os métodos analíticos utilizados para determinação desses analitos são demorados, com alto consumo de solventes e necessitam de extração e /ou pré-concentração. A extração Soxhlet é recomendada e a etapa de concentração do extrato orgânico é geralmente feita por roto-evaporação ou fluxo de nitrogênio. Nesses procedimentos ocorrem perdas por evaporação das espécies mais voláteis como antraceno e fenantreno. Nesse contexto, a extração em fase sólida com membrana aliada a espectroscopia de fluorescência diretamente na membrana se mostra uma alternativa sensível, rápida e de baixo custo que, associada à calibração de ordem superior, permite quantificar esses compostos em diversas matrizes. Esse conjunto de técnicas possui uma limitação da sua aplicação em sistemas reais: possíveis particulados em suspensão na solução da amostra ficam retidos na membrana após a extração e podem comprometer a detecção de fluorescência por efeito filtro, inviabilizando a aplicação em matrizes mais complexas. Assim, no presente trabalho foi desenvolvida uma metodologia para determinação de antraceno e fenantreno em amostras de águas e de solo utilizando a extração em fase sólida em membrana de náilon, espectroscopia de fluorescência direto na membrana e calibração de 2ª ordem (PARAFAC). A estratégia utilizada para evitar a interferência de particulados retidos na filtração foi realizar a detecção na face oposta à filtração. Os resultados obtidos mostraram que o método proposto permite identificar fenantreno e antraceno, e quantificar o fenantreno de forma simples, rápida e eficaz em amostras de solos e água de torneira contendo os dois isômeros.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentQuímicapt_BR
dc.publisher.programPrograma de Pós-Graduação em Químicapt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICApt_BR
Aparece nas coleções:Centro de Ciências Exatas e da Natureza (CCEN) - Programa de Pós-Graduação em Química

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Arquivototal.pdfArquivo total2,4 MBAdobe PDFVisualizar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons