Use este identificador para citar ou linkar para este item:
https://repositorio.ufpb.br/jspui/handle/123456789/18273
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Caldeira, Carolina Albuquerque | - |
dc.date.accessioned | 2020-10-25T23:27:05Z | - |
dc.date.available | 2020-10-23 | - |
dc.date.available | 2020-10-25T23:27:05Z | - |
dc.date.issued | 2020-02-18 | - |
dc.identifier.uri | https://repositorio.ufpb.br/jspui/handle/123456789/18273 | - |
dc.description.abstract | In this work, a battery energy storage system is used along with a bidirectional three-phase converter in order to provide ancillary services to a distribution system, whose voltage and power levels have been adapted in scale from the measured consumption data from the Instituto Federal da Paraíba. Ancillary services include harmonic compensation from non-linear loads connected to the common coupling point, power factor correction and the active power injection by the battery-based energy storage system at peak and off-peak times, in order to minimize demand costs and to reduce power flow. To perform harmonic reduction in the current grid, a proportional-integral control was implemented, in which only the grid current measured was used to perform the control. The battery-based energy storage system’s current control was also performed by the same controller, where it was only necessary to measure the current circulating in the battery, also enabling the control of its state of charge. The energy management, in turn, was carried out according to the load curve analysis of the distribution system under study and the load status of the storage system, where were defined both the peak and off-peak periods in which the the battery would be charged and discharged. The results were obtained through simulations carried out on MATLAB/Simulink® software the experiments were carried out in the Laboratório de Otimização de Sistemas de Energia, which allowed the total harmonic distortion and power factor’s analysis using non-linear load, and the energy analysis using the load curve. Different scenarios that validated the contribution of the proposed system in the provision of ancillary services in the distribution system under study were analyzed. | pt_BR |
dc.description.provenance | Submitted by ANA KARLA PEREIRA RODRIGUES (anakarla@biblioteca.ufpb.br) on 2020-10-23T06:44:48Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) CarolinaAlbuquerqueCaldeira_Dissert.pdf: 15925372 bytes, checksum: f52d326722d90aaf9ea6c568385540ff (MD5) | en |
dc.description.provenance | Approved for entry into archive by Biblioteca Digital de Teses e Dissertações BDTD (bdtd@biblioteca.ufpb.br) on 2020-10-25T23:27:05Z (GMT) No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) CarolinaAlbuquerqueCaldeira_Dissert.pdf: 15925372 bytes, checksum: f52d326722d90aaf9ea6c568385540ff (MD5) | en |
dc.description.provenance | Made available in DSpace on 2020-10-25T23:27:05Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) CarolinaAlbuquerqueCaldeira_Dissert.pdf: 15925372 bytes, checksum: f52d326722d90aaf9ea6c568385540ff (MD5) Previous issue date: 2020-02-18 | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES | pt_BR |
dc.language | por | pt_BR |
dc.publisher | Universidade Federal da Paraíba | pt_BR |
dc.rights | Acesso aberto | pt_BR |
dc.rights.uri | http://creativecommons.org/licenses/by-nd/3.0/br/ | * |
dc.subject | Sistemas de armazenamento de energia em baterias | pt_BR |
dc.subject | Serviços ancilares | pt_BR |
dc.subject | Gerenciamento de energia | pt_BR |
dc.subject | Qualidade de energia elétrica | pt_BR |
dc.subject | Battery energy storage systems | pt_BR |
dc.subject | Ancillary services | pt_BR |
dc.subject | Energy management | pt_BR |
dc.subject | Electric power quality | pt_BR |
dc.title | Análise do fornecimento de serviços ancilares por um sistema de armazenamento de energia baseado em bateria em uma rede de distribuição | pt_BR |
dc.type | Dissertação | pt_BR |
dc.contributor.advisor1 | Salvadori, Fabiano | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/0735993399553280 | pt_BR |
dc.contributor.advisor2 | Gehrke, Camila Seibel | - |
dc.contributor.advisor2Lattes | http://lattes.cnpq.br/5697056374420574 | pt_BR |
dc.creator.Lattes | http://lattes.cnpq.br/1451354454096797 | pt_BR |
dc.description.resumo | Neste trabalho, um sistema de armazenamento de energia por baterias é utilizado em conjunto com um conversor trifásico bidirecional com o intuito de fornecer serviços ancilares a um sistema de distribuição, cujos níveis de tensão e potência foram adaptados em escala dos dados de consumo medido provenientes do Instituto Federal da Paraíba. Os serviços ancilares incluem a compensação de harmônicos, provenientes das cargas não-lineares conectadas ao ponto de acoplamento comum, correção do fator de potência e a injeção de potência ativa por parte do sistema de armazenamento de energia baseado em baterias em horários de ponta e fora de ponta, visando a minização dos custos com demanda e a redução do fluxo de potência. Para realizar a redução de harmônicos na corrente da rede, foi implementado o controle proporcional-integral, no qual utilizou-se apenas a corrente medida na rede para realizar o controle. O controle da corrente do sistema de armazenamento de energia baseado em baterias também foi realizado pelo mesmo controlador, onde foi necessário apenas a leitura da corrente que circulava na bateria, permitindo também o controle de seu estado de carga. O gerenciamento de energia, por sua vez, foi realizado de acordo com a análise de curva de carga do sistema de distribuição em estudo e com o estado de carga do sistema de armazenamento, onde foram definidos o período de ponta e fora de ponta em que a bateria seria carregada e descarregada. Os resultados foram obtidos através de simulações realizadas no software MATLAB/Simulink® e os experimentos foram realizados no Laboratório de Otimização de Sistemas de Energia, permitindo a análise da distorção harmônica total e do fator de potência com o uso de carga-não linear, e a análise de energia com o uso da curva de carga. Foram analisados diferentes cenários que validaram a contribuição do sistema proposto no fornecimento de serviços ancilares no sistema de distribuição em estudo. | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Engenharia Elétrica | pt_BR |
dc.publisher.program | Programa de Pós-Graduação em Engenharia Elétrica | pt_BR |
dc.publisher.initials | UFPB | pt_BR |
dc.subject.cnpq | CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA | pt_BR |
Aparece nas coleções: | Centro de Energias Alternativas e Renováveis (CEAR) - Programa de Pós-Graduação em Engenharia Elétrica |