dc.creatorBarros Filho, Genilton de França-
dc.date.accessioned2020-12-13T19:23:15Z-
dc.date.available2021-06-29-
dc.date.available2020-12-13T19:23:15Z-
dc.date.issued2020-06-29-
dc.identifier.urihttps://repositorio.ufpb.br/jspui/handle/123456789/18708-
dc.description.abstractValves separate atria and ventricles of the human heart. They are important for controlling blood flow. Therefore, the detection of valve diseases is important for human health. Currently, the doctor, from the video obtained in the echocardiogram exam, performs an image freeze, manually measures the area of the mitral valve, and then finalizes the diagnosis. This procedure takes time and may contain some values of areas that are not real, as the video may be frozen at an inappropriate time. Thus, this work aims to detect the maximum opening area of the mitral valves, in an automated way, using digital image processing, which consists, in short terms, of signal processing in matrix format. This information is very importance for the identification of stenosis (inability of the valve to open completely due to a process of histological alteration that causes loss of elasticity and alters its form). Therefore, from the videos of 3D transesophageal echocardiogram exams, it was possible to develop a graphical interface, in Python language, capable of loading the videos, performing digital processing, providing the value of the maximum valve opening area and the following diagnosis: “THERE IS STENOSIS” or “THERE IS NO STENOSIS”. The values selected manually, by cardiologists, and the values of the system created were compared, showing that the system fullfield its proposal. In addition, tests were made with 3D printing applications using the 3D transesophageal echocardiogram exams. It turns out that it is possible to obtain prototypes of mitral valves from this examination, maintaining their anatomical characteristics and printing in their real size.pt_BR
dc.description.provenanceSubmitted by Cristhiane Guerra (cristhiane.guerra@academico.ufpb.br) on 2020-11-30T17:37:15Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) GeniltonDeFrançaBarrosFilho_Dissert.pdf: 4738809 bytes, checksum: a04e022aa300c9477deaada47e2c0c40 (MD5)en
dc.description.provenanceApproved for entry into archive by Biblioteca Digital de Teses e Dissertações BDTD (bdtd@biblioteca.ufpb.br) on 2020-12-13T19:23:15Z (GMT) No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) GeniltonDeFrançaBarrosFilho_Dissert.pdf: 4738809 bytes, checksum: a04e022aa300c9477deaada47e2c0c40 (MD5)en
dc.description.provenanceMade available in DSpace on 2020-12-13T19:23:15Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) GeniltonDeFrançaBarrosFilho_Dissert.pdf: 4738809 bytes, checksum: a04e022aa300c9477deaada47e2c0c40 (MD5) Previous issue date: 2020-06-29en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rightsAcesso embargadopt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/*
dc.subjectEcocardiogramapt_BR
dc.subjectValva mitralpt_BR
dc.subjectProcessamento digital de imagenspt_BR
dc.subjectEstenosept_BR
dc.subjectImpressão 3Dpt_BR
dc.subjectEchocardiogrampt_BR
dc.subjectMitral valvept_BR
dc.subjectDigital image processingpt_BR
dc.subjectStenosispt_BR
dc.subject3D printingpt_BR
dc.titleObtenção de medidas de valvas mitrais a partir de ecocardiograma utilizando processamento digital de imagenspt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Rodrigues, Marcelo Cavalcanti-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2140285341359128pt_BR
dc.contributor.advisor-co1Melo, Marcelo Dantas Tavares de-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/3949877047228534pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/9671915623110522pt_BR
dc.description.resumoOs átrios e os ventrículos do coração humano são separados por meio de valvas atrioventriculares. Elas são importantes para o controle do fluxo sanguíneo. Logo, a detecção de valvopatias (doenças relacionadas as valvas) é de fundamental importância para a saúde humana. Atualmente, o médico a partir do vídeo obtido no exame de ecocardiograma, executa um congelamento da imagem e mede de forma manual a área da valva mitral e então finaliza o diagnóstico. Esse procedimento leva tempo e pode conter alguns valores de áreas que não são os reais, pois o vídeo pode ser congelado em um momento não adequado. Assim, este trabalho tem como objetivo a detecção da área de máxima abertura das valvas mitrais, de maneira automatizada, por meio de processamento digital de imagens, que consiste, de maneira resumida, no processamento de sinais no formato de matrizes. Esse valor é de grande importância para a identificação da presença ou não de estenose (incapacidade da valva de se abrir completamente devido a um processo de alteração histológica que a faz perder elasticidade e altera a sua forma). Portanto, a partir dos vídeos advindos de exames de ecocardiograma transesofágico 3D (ETE 3D), foi possível desenvolver uma interface gráfica, em linguagem Python, capaz de carregar o arquivo, realizar o processamento digital, fornecer o valor da área de máxima abertura valvar e estabelecer o seguinte diagnóstico: “HÁ ESTENOSE” ou “NÃO HÁ ESTENOSE”. Comparou-se os valores obtidos manualmente, por cardiologistas, e os valores do sistema criado e concluiu-se que o sistema obteve êxito, quanto a sua proposta. Além disso, testou-se a aplicação da impressão 3D a partir de exames de ETE 3D. Constatou-se que é possível obter protótipos de valvas mitrais a partir deste exame, mantendo suas características anatômicas e imprimindo no seu tamanho real.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEngenharia Mecânicapt_BR
dc.publisher.programPrograma de Pós-Graduação em Engenharia Mecânicapt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA MECANICApt_BR
Aparece nas coleções:Centro de Tecnologia (CT) - Programa de Pós-Graduação em Engenharia Mecânica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
GeniltonDeFrançaBarrosFilho_Dissert.pdf4,63 MBAdobe PDFVisualizar/Abrir    Solicitar uma cópia


Este item está licenciada sob uma Licença Creative Commons Creative Commons