| dc.description.abstract | Wind generators have recurring operating interruptions due to internal failures. Internal failures are difficult to detect and may silently lead to machine damages since they occur between turns, being named turn-to-turn, or between turn and machine housing, being named turn-to-ground. Thus, these plants must be constantly monitored so that these faults are detected in their initial stage. This early detection makes it possible to reduce maintenance costs while decreasing wind turbine downtime. This work proposes a strategy for noninvasive detecting stator failures in its initial stage through a classifier module that analyzes the stator current patterns. This classifier is based on a Multilayer Perceptron (MLP), that is a class of feedforward artificial neural network (ANN), which was trained using a dataset generated by a mathematical model of the PMSG-based wind turbine. The results show that the MLP classifier is able to detect the proposed problem with 97.62% global accuracy. In addition, detection was performed at a initial stage of 1% to 4% of faulty turns with 100% accuracy, contributing to continuous and noninvasive detection of internal wind turbine stator faults. | pt_BR |
| dc.description.provenance | Submitted by Jackson Nunes (jackson@biblioteca.ufpb.br) on 2021-05-31T14:41:31Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) BrunoAdônisDeSá_Dissert.pdf: 7813407 bytes, checksum: b834d60d1e53ba7df781057a80d811e2 (MD5) | en |
| dc.description.provenance | Approved for entry into archive by Biblioteca Digital de Teses e Dissertações BDTD (bdtd@biblioteca.ufpb.br) on 2021-06-01T20:08:10Z (GMT) No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) BrunoAdônisDeSá_Dissert.pdf: 7813407 bytes, checksum: b834d60d1e53ba7df781057a80d811e2 (MD5) | en |
| dc.description.provenance | Made available in DSpace on 2021-06-01T20:08:10Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) BrunoAdônisDeSá_Dissert.pdf: 7813407 bytes, checksum: b834d60d1e53ba7df781057a80d811e2 (MD5) Previous issue date: 2020-01-31 | en |
| dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES | pt_BR |
| dc.language | por | pt_BR |
| dc.publisher | Universidade Federal da Paraíba | pt_BR |
| dc.rights | Acesso embargado | pt_BR |
| dc.rights.uri | http://creativecommons.org/licenses/by-nd/3.0/br/ | * |
| dc.subject | Aprendizagem de máquina | pt_BR |
| dc.subject | Detecção de faltas no estator | pt_BR |
| dc.subject | Energia eólica | pt_BR |
| dc.subject | Gerador síncrono de ímã permanente | pt_BR |
| dc.subject | Perceptron multicamadas | pt_BR |
| dc.subject | Machine learning | pt_BR |
| dc.subject | Stator fault detection | pt_BR |
| dc.subject | Wind energy | pt_BR |
| dc.subject | Permanent magnet synchronous generator | pt_BR |
| dc.title | Uma abordagem baseada em perceptron multicamadas para detecção de faltas no estator de geradores eólicos do tipo PMSG | pt_BR |
| dc.type | Dissertação | pt_BR |
| dc.contributor.advisor1 | Siebra, Clauirton de Albuquerque | - |
| dc.contributor.advisor1Lattes | http://lattes.cnpq.br/7707799028683443 | pt_BR |
| dc.contributor.advisor-co1 | Barros, Camila Mara Vital | - |
| dc.contributor.advisor-co1Lattes | http://lattes.cnpq.br/1315327332959469 | pt_BR |
| dc.creator.Lattes | http://lattes.cnpq.br/2433838688491425 | pt_BR |
| dc.description.resumo | Os geradores eólicos apresentam interrupções de operação recorrentes devido à ocorrência de falhas internas. Falhas internas são de difícil detecção e que podem conduzir, silenciosamente, a danos na máquina e podem ocorrer entre as espiras, sendo denominadas espira-espira, ou entre espiras e a carcaça da máquina, sendo denominadas espira-terra. Assim, estas plantas devem ser constantemente monitoradas para que essas falhas sejam detectadas em seu estágio inicial. Essa detecção precoce possibilita a redução do custo de manutenção, ao mesmo tempo em que diminui o tempo de inatividade das turbinas eólicas. Este trabalho propõe uma estratégia para detectar falhas no estator em seu estágio inicial de forma não invasiva por meio de um módulo classificador que analisa os padrões da corrente do estator. Este classificador baseia-se em uma rede neural do tipo perceptron multicamadas (do inglês, Multilayer Perceptron - MLP), que foi treinada utilizando um conjunto de dados de instâncias geradas por meio de um modelo matemático de uma turbina eólica baseada no PMSG. Os resultados mostram que o classificador MLP é capaz de detectar o problema proposto com 97,62% de acurácia global. Além disso, a detecção foi alcançada em um estágio inicial, de 1% a 4% de espiras defeituosas com acurácia de 100%, contribuindo para uma detecção continua e não invasiva de falhas internas ao estator da turbina eólica. | pt_BR |
| dc.publisher.country | Brasil | pt_BR |
| dc.publisher.department | Informática | pt_BR |
| dc.publisher.program | Programa de Pós-Graduação em Informática | pt_BR |
| dc.publisher.initials | UFPB | pt_BR |
| dc.subject.cnpq | CNPQ::CIENCIAS EXATAS E DA TERRA::CIENCIA DA COMPUTACAO | pt_BR |
| Aparece nas coleções: | Centro de Informática (CI) - Programa de Pós-Graduação em Informática | |