Skip navigation

Use este identificador para citar ou linkar para este item: https://repositorio.ufpb.br/jspui/handle/123456789/21112
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSouza, Gracielle Ferreira de-
dc.date.accessioned2021-09-30T20:57:36Z-
dc.date.available2021-05-28-
dc.date.available2021-09-30T20:57:36Z-
dc.date.issued2021-03-24-
dc.identifier.urihttps://repositorio.ufpb.br/jspui/handle/123456789/21112-
dc.description.abstractIn Brazil, there is a deficit in sewage collection and treatment services and for the universalization of sewage systems, investments in infrastructure are essential. However, one of the main obstacles to the expansion of the sewage system in the country is the high cost of implementing the sewage collection network. A design parameter that can influence the costs of the sewage collection network is the shear stress. In this sense, this research aims to analyze the effects of the adoption of minimum values of tension for the dimensioning of the sewage collection network on the associated costs for various topographic scenarios. For the purpose of study, with the aid of the CEsg software, 50 scenarios were designed, with identical traces of the collecting network and with different configurations of topography and minimum shear stress. The results indicated that the diameter of the collectors remained constant with the variation of the tensile stress, reaching the minimum value of 150 mm and that there is no difference in cost between the 0.6 and 1.0 Pa shear stresses for all the studied scenarios. It was found that from the 1.0 Pa shear tension, the cost increased with the increase in the tractive tension adopted in the project, and for more rugged áreas, the increase in cost was expressed as negligible. In general, it was found that the shear tension and the topography play determinant roles in the cost, the higher the value of the tension and the lower the slope of the topography, the greater the cost of implementing the sewage collection network. However, in terrains with steeper topographies, the use of shear tension higher than that suggested by the standard is allowed, in more than 3.0 Pa, with a minimum incidence of additional costs in relation to the value of 0.6 Pa or 1,0 Pa.pt_BR
dc.description.provenanceSubmitted by Ariadne Cristina Moura (ariadne.moura@academico.ufpb.br) on 2021-09-24T13:49:22Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) GracielleFerreiraDeSouza_Dissert.pdf: 11475608 bytes, checksum: 60d1f5e7fe904f6a61bb83f0da268b9d (MD5)en
dc.description.provenanceApproved for entry into archive by Biblioteca Digital de Teses e Dissertações BDTD (bdtd@biblioteca.ufpb.br) on 2021-09-30T20:57:36Z (GMT) No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) GracielleFerreiraDeSouza_Dissert.pdf: 11475608 bytes, checksum: 60d1f5e7fe904f6a61bb83f0da268b9d (MD5)en
dc.description.provenanceMade available in DSpace on 2021-09-30T20:57:36Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) GracielleFerreiraDeSouza_Dissert.pdf: 11475608 bytes, checksum: 60d1f5e7fe904f6a61bb83f0da268b9d (MD5) Previous issue date: 2021-03-24en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rightsAcesso abertopt_BR
dc.rightsAttribution-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/*
dc.subjectSistema de esgotamento sanitáriopt_BR
dc.subjectProfundidadept_BR
dc.subjectDeclividadept_BR
dc.subjectTensão trativa mínimapt_BR
dc.subjectOrçamentopt_BR
dc.subjectSewerage systempt_BR
dc.subjectDepthpt_BR
dc.subjectDeclivitypt_BR
dc.subjectMinimum shear stresspt_BR
dc.subjectBudgetpt_BR
dc.titleImpacto da tensão trativa adotada no dimensionamento de rede coletora de esgoto sanitário sobre os seus custos construtivospt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Athayde Junior, Gilson Barbosa-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/8220830326280125pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/0414869464759003pt_BR
dc.description.resumoNo Brasil, existe um déficit nos serviços de coleta e tratamento de esgotos, e para que ocorra a universalização dos sistemas de esgotamento sanitário, fazem-se imprescindíveis investimentos em infraestrutura. No entanto, um dos principais obstáculos para expansão do sistema de esgotamento sanitário no país é o alto custo da implantação da rede coletora de esgoto. Um parâmetro de projeto que pode influenciar nos custos da rede coletora de esgotos é a tensão trativa. Nesse sentido, esta pesquisa objetivou-se analisar os efeitos da adoção de valores mínimos de tensão trativa para o dimensionamento de rede coletora de esgoto sanitário sobre os custos associados para variados cenários topográficos. Para efeito de estudo, com o auxílio do software CEsg, foi realizado o dimensionamento de 50 cenários, com traçados idênticos da rede coletora e com diferentes configurações de topografia e tensão trativa mínima. Os resultados indicaram que o diâmetro dos coletores se manteve constante com a variação da tensão trativa, atingindo o valor mínimo de 150 mm e que não existe diferença de custo entre as tensões trativas 0,6 e 1,0 Pa para todos os cenários estudados. Verificou-se que a partir da tensão trativa de 1,0 Pa, o custo apresentou crescimento com o aumento da tensão trativa adotada em projeto, sendo que para áreas mais acidentadas, o acréscimo no custo expressou-se irrisório. De uma forma geral, constatou-se que a tensão trativa e a topografia exercem papéis determinantes no custo; quanto maior o valor da tensão e quanto menor a declividade da área, maior é o custo de implantação da rede coletora de esgoto. Contudo, em terrenos com topografias mais íngremes, admite-se o uso de tensão trativa superiores ao sugerido por norma, no mais que 3,0 Pa, com incidência mínima de custos adicionais em relação ao valor de 0,6 ou 1,0 Pa.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEngenharia Civil e Ambientalpt_BR
dc.publisher.programPrograma de Pós-Graduação em Engenharia Civil e Ambientalpt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA CIVILpt_BR
Aparece nas coleções:Centro de Tecnologia (CT) - Programa de Pós-Graduação em Engenharia Civil e Ambiental

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
GracielleFerreiraDeSouza_Dissert.pdf11,21 MBAdobe PDFVisualizar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons