dc.creatorFlores, Thommas Kevin Sales-
dc.date.accessioned2022-05-11T16:24:42Z-
dc.date.available2021-03-17-
dc.date.available2022-05-11T16:24:42Z-
dc.date.issued2021-02-22-
dc.identifier.urihttps://repositorio.ufpb.br/jspui/handle/123456789/22801-
dc.description.abstractGiven the scarcity of water resources concomitantly with the prospects of urbanization, it has become essential to establish practices that make it possible to reduce losses and improve the water distribution system. Therefore, over the years, several control techniques have been applied in these systems, mainly focusing on the reduction of hydraulic pressure in the ducts, among them the adaptive control. However, the method adopted for its tuning is empirical and exhaustive due to the large number of parameters to be adjusted. Moreover, the criterion adopted by this class of controller is the Mean Squared Error (MSE) for minimizing the tracking error and parametric estimation, however, this criterion is limited to extract information only from the first and second order statistical moments, consequently losing information contained in the higher order statistical moments. Therefore, the present work uses as a criterion for minimizing the tracking error and parameter estimation of a Reference Model Adaptive Controller the Maximum Correntropy with Gaussian kernel. This controller was implemented using Matlab in a LABVIEW environment for pressure control in an experimental water pumping system. The results obtained showed that the controller presents similar characteristics to the control that uses the MSE criterion, for errors close to zero, with a maximum error of 15% during the demand variation, percentage overshoot less than 5% and steady state error less than 2%. However, it is robust to outliers, which does not happen when the MSE criterion is used, this allows for greater reliability in water supply systems that use the controller with the MCC.pt_BR
dc.description.provenanceSubmitted by Fernanda Ferreira (fernandaferreira@biblioteca.ufpb.br) on 2022-05-02T13:53:04Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) ThommasKevinSalesFlores_Dissert.pdf: 10014321 bytes, checksum: a395371c23a58435c9d3dcbf077e0523 (MD5)en
dc.description.provenanceApproved for entry into archive by Biblioteca Digital de Teses e Dissertações BDTD (bdtd@biblioteca.ufpb.br) on 2022-05-11T16:24:42Z (GMT) No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) ThommasKevinSalesFlores_Dissert.pdf: 10014321 bytes, checksum: a395371c23a58435c9d3dcbf077e0523 (MD5)en
dc.description.provenanceMade available in DSpace on 2022-05-11T16:24:42Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) ThommasKevinSalesFlores_Dissert.pdf: 10014321 bytes, checksum: a395371c23a58435c9d3dcbf077e0523 (MD5) Previous issue date: 2021-02-22en
dc.description.sponsorshipNenhumapt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rightsAcesso abertopt_BR
dc.rightsAttribution-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/*
dc.subjectControle adaptativo indiretopt_BR
dc.subjectCritério da máxima correntropiapt_BR
dc.subjectSistemas de bombeamento de águapt_BR
dc.subjectModelo de referênciapt_BR
dc.subjectIndirect adaptive controlpt_BR
dc.subjectMaximum correntropia criterionpt_BR
dc.subjectWater pumping systemspt_BR
dc.subjectReference modelpt_BR
dc.titleControle adaptativo utilizando o critério da máxima correntropia aplicado a um sistema de bombeamento de águapt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Villanueva, Juan Moises Maurício-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1446817462218646pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/0630479458408181pt_BR
dc.description.resumoDiante da escassez dos recursos hídricos concomitantemente com as perspectivas de urbanização, tornou-se fundamental estabelecer práticas que possibilitam reduzir perdas e aprimorar o sistema de distribuição de água. Portanto, ao longo dos anos, diversas técnicas de controles foram aplicadas nestes sistemas, principalmente com o foco na redução da pressão hidráulica nos ductos, entre elas o controle adaptativo. No entanto, o método adotado para sua sintonia é empírico e exaustivo devido à grande quantidade de parâmetros a serem ajustados. Além disso, o critério adotado por esta classe de controlador é o Erro Médio Quadrático (EMQ) para minimização do erro de rastreamento e estimação paramétrica, porém, este critério limita-se a extrair informação apenas dos momentos estatísticos de primeira e segunda ordem, consequentemente perdendo informações contidas nos momentos estatísticos de ordem superior. Deste modo, o presente trabalho utiliza como critério para minimização do erro de rastreamento e estimação dos parâmetros de um Controlador Adaptativo por Modelo de Referência a Máxima Correntropia com kernel Gaussiano. Este controlador foi implementado utilizando Matlab em ambiente Labview para o controle da pressão em um sistema de bombeamento de água experimental. Os resultados obtidos demonstraram que o controlador apresenta características similares ao controle que utiliza o critério EMQ, para erros próximos de zero, com erro máximo de 15% durante a variação da demanda, sobrevalor percentual menor que 5% e erro em regime estacionário menor que 2%. Todavia, mostra-se robusto a outliers, fato que não acontece quando é utilizado o critério EMQ, isto permite maior confiabilidade nos sistemas de abastecimento de água que utilizarem o controlador com o MCC.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEngenharia Elétricapt_BR
dc.publisher.programPrograma de Pós-Graduação em Engenharia Elétricapt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA ELETRICApt_BR
Aparece nas coleções:Centro de Energias Alternativas e Renováveis (CEAR) - Programa de Pós-Graduação em Engenharia Elétrica