dc.description.abstractThe research proposes to investigate the modulation technique with the One-Cycle Control (OCC) applied to three-phase inverters, with a focus on reducing the Common Mode Voltage (CMV) in photovoltaic systems connected to the grid. The proposed method is explained by its mathematical modeling, being compiled in a photovoltaic system plant (processed in the dedicated Matlab software for simulations), with a power generation capacity of 3kW, composed of a matrix of photovoltaic plates and an inverter. of three-phase voltage. The simulation results of the OCC technique are compared with results of the SVPWM technique already published in the literature. The Common Mode Voltage is considered a problem in electrical systems. Its emergence occurs by Electromagnetic Interference - EMI usually caused by non-linear loads connected to the electrical network. Electronic devices that operate with low nominal voltage values are more susceptible to CMV. In systems connected to the grid, CMV causes complications in supplying the voltage generated by the PV array, transmitting harmonic currents to the grid. The OCC controller has a relevant characteristic in the perspective of reducing the Common Mode Voltage in photovoltaic systems connected to the grid, thus pointing out improvements in the quality of the output voltage signal produced by these systems.pt_BR
dc.description.provenanceSubmitted by Fernando Augusto Alves Vieira (fernandovieira@biblioteca.ufpb.br) on 2022-09-19T10:57:02Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) JoséRamonNunesFerreira_Dissert.pdf: 4515494 bytes, checksum: 46bf28d29de95834406215ddfe9725fe (MD5)en
dc.description.provenanceApproved for entry into archive by Biblioteca Digital de Teses e Dissertações BDTD (bdtd@biblioteca.ufpb.br) on 2022-09-28T19:44:52Z (GMT) No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) JoséRamonNunesFerreira_Dissert.pdf: 4515494 bytes, checksum: 46bf28d29de95834406215ddfe9725fe (MD5)en
dc.description.provenanceMade available in DSpace on 2022-09-28T19:44:52Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) JoséRamonNunesFerreira_Dissert.pdf: 4515494 bytes, checksum: 46bf28d29de95834406215ddfe9725fe (MD5) Previous issue date: 2021-02-26en
dc.description.sponsorshipNenhumapt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rightsAcesso embargadopt_BR
dc.rightsAttribution-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/*
dc.subjectTensão de modo comumpt_BR
dc.subjectInterferências eletromagnéticaspt_BR
dc.subjectSVPWMpt_BR
dc.subjectOCCpt_BR
dc.subjectSistemas fotovoltaicospt_BR
dc.subjectCommon mode voltagept_BR
dc.subjectElectromagnetic interferencept_BR
dc.subjectPWM methodspt_BR
dc.subjectPhotovoltaic systemspt_BR
dc.titleTécnicas de modulação para redução da tensão de modo comum em sistemas fotovoltaicos conectados à redept_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Souza, Márcio Rodrigo de Araújo-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/6252231670995980pt_BR
dc.contributor.advisor2Lock, Alberto Soto-
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/7623349795638505pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/7074303515196287pt_BR
dc.description.resumoA pesquisa propõe investigar a técnica de modulação com o Controle de Ciclo Único (One Cycle Control – OCC) aplicado a inversores trifásicos, com foco na redução da Tensão de Modo Comum (CMV – Common Mode Voltage) em sistemas fotovoltaicos conectados à rede. O método proposto é explanado pela sua modelagem matemática, sendo compilado numa planta de sistema fotovoltaico (processado no software Matlab dedicado para simulações), com capacidade de geração de potência de 3kW, composto por uma matriz de placas fotovoltaicas (arranjo PV) e um inversor de tensão trifásico. Os resultados de simulação da técnica OCC são comparados com resultados da técnica SVPWM já despargida na literatura. A Tensão de Modo Comum é considerada um problema em sistemas elétricos. Seu surgimento ocorre por Interferências Eletromagnéticas - EMI (Electromagnetic Interference) geralmente provocadas por cargas não lineares conectadas à rede elétrica. Dispositivos eletrônicos que operam com valores de tensão nominal baixos são mais susceptíveis à CMV. Em sistemas conectados à rede, a CMV causa complicações no fornecimento da tensão gerada pelo arranjo PV, transmitindo para rede harmônicos de corrente. O controlador OCC possui característica relevante na perspectiva da redução da Tensão de Modo Comum em sistemas fotovoltaicos conectados à rede apontando, dessa forma, melhorias na qualidade do sinal de tensão de saída produzida por esses sistemas.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEngenharia de Energias Renováveispt_BR
dc.publisher.programPrograma de Pós-Graduação em Energias Renováveispt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::ENGENHARIASpt_BR
Aparece nas coleções:Centro de Energias Alternativas e Renováveis (CEAR) - Programa de Pós-Graduação em Energias Renováveis

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
JoséRamonNunesFerreira_Dissert.pdf4,41 MBAdobe PDFVisualizar/Abrir    Solicitar uma cópia


Este item está licenciada sob uma Licença Creative Commons Creative Commons