Skip navigation

Use este identificador para citar ou linkar para este item: https://repositorio.ufpb.br/jspui/handle/123456789/24919
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBrasil, Francisco Carlos Leite-
dc.date.accessioned2022-10-13T13:20:09Z-
dc.date.available2021-05-11-
dc.date.available2022-10-13T13:20:09Z-
dc.date.issued2021-02-25-
dc.identifier.urihttps://repositorio.ufpb.br/jspui/handle/123456789/24919-
dc.description.abstractThis work consists of a control strategy for unbalanced loads, based on a system consisting of a proposed three-phase Phase-Locked Loop - PLL, a power control and the One Cycle Control - OCC technique. Such a strategy has as methodology the control of power, from the input resistance and the positive sequence component of the load current. The three phase PLL is used to track the phase and frequency, and the OCC modulator from the conventional OCC. The control system was implemented in a simulation environment using the PSCAD / EMTDC software, with the following technical characteristics: nominal power of 1 kVA; rated voltage of 220 V; line inductance equal to 0,2 mH; RL load (50 Ω and 2 mH) and frequency of 60 Hz. As a way of evaluating the performance of the system, several simulations were carried out with the implementation of disturbance events in the network, verifying its behavior during the transient and stationary regime. In such work, it is intended to achieve the following goals: 1) to implement the OCC technique as part of the control system; 2) obtain symmetrical and continuous load currents during disturbance events in the network with harmonic distortion levels within the regulatory limits, and 3) maintain the active and reactive power constant in the load during the transient and stationary regime when the occurrence of network disturbances.pt_BR
dc.description.provenanceSubmitted by Fernando Augusto Alves Vieira (fernandovieira@biblioteca.ufpb.br) on 2022-10-04T16:26:58Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) FranciscoCarlosLeiteBrasil_Dissert.pdf: 2384111 bytes, checksum: 7136d498a1a7a047761f52305dc05e86 (MD5)en
dc.description.provenanceApproved for entry into archive by Biblioteca Digital de Teses e Dissertações BDTD (bdtd@biblioteca.ufpb.br) on 2022-10-13T13:20:09Z (GMT) No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) FranciscoCarlosLeiteBrasil_Dissert.pdf: 2384111 bytes, checksum: 7136d498a1a7a047761f52305dc05e86 (MD5)en
dc.description.provenanceMade available in DSpace on 2022-10-13T13:20:09Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) FranciscoCarlosLeiteBrasil_Dissert.pdf: 2384111 bytes, checksum: 7136d498a1a7a047761f52305dc05e86 (MD5) Previous issue date: 2021-02-25en
dc.description.sponsorshipNenhumapt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rightsAcesso abertopt_BR
dc.rightsAttribution-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/*
dc.subjectInversorpt_BR
dc.subjectControlept_BR
dc.subjectCargas desbalanceadaspt_BR
dc.subjectOne cycle controlpt_BR
dc.subjectSistema fotovoltaicopt_BR
dc.subjectPLLpt_BR
dc.subjectSimulador PSCAD/EMTDCpt_BR
dc.subjectInverterpt_BR
dc.subjectControlpt_BR
dc.subjectLoads unbalancespt_BR
dc.subjectOne-cycle control techniquept_BR
dc.subjectPhotovoltaico sistempt_BR
dc.subjectPSCAD/EMTDC simulatorpt_BR
dc.titleControlador de cargas desbalanceadas em sistema de geração fotovoltaica conectado à rede trifásica de distribuiçãopt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Gurgel, José Maurício Alves de Matos-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/8118978612486649pt_BR
dc.contributor.advisor2Lock, Soto-
dc.contributor.advisor2Latteshttp://lattes.cnpq.br/7623349795638505pt_BR
dc.contributor.advisor-co1Fernandes, Darlan Alexandria-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/4875481653656310pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/4646788783678848pt_BR
dc.description.resumoEste trabalho consiste de uma estratégia de controle para cargas desbalanceadas, baseado num sistema constituído de um Phase-Locked Loop - PLL trifásico proposto, um controle de potência e a técnica One Cycle Control - OCC. Tal estratégia tem como metodologia o controle da potência, a partir da resistência de entrada e a componente de sequência positiva da corrente de carga. Utiliza-se o PLL trifásico para rastreio da fase e frequência, e o modulador OCC a partir do OCC convencional. O sistema de controle foi implementado em ambiente de simulação através do software PSCAD/EMTDC, com as seguintes características técnicas: potência nominal de 1 kVA; tensão nominal de 220 V; indutância da linha igual a 0,2 mH; carga RL (50 Ω e 2 mH) e frequência de 60 Hz. Como forma de avaliar o desempenho do sistema, foram realizadas diversas simulações com a implementação de eventos de perturbações na rede, verificando o seu comportamento durante o regime transitório e estacionário. Em tal trabalho, pretende-se atingir as seguintes metas: 1) implementar a técnica OCC como parte do sistema de controle; 2) obter correntes de carga contínua e simétricas durante eventos de perturbações na rede com níveis de distorções de harmônicos dentro dos limites regulatórios, e 3) manter a potência ativa e reativa constantes na carga durante o regime transitório e estacionário quando da ocorrência de eventos de perturbações na rede.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEngenharia de Energias Renováveispt_BR
dc.publisher.programPrograma de Pós-Graduação em Energias Renováveispt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::ENGENHARIASpt_BR
Aparece nas coleções:Centro de Energias Alternativas e Renováveis (CEAR) - Programa de Pós-Graduação em Energias Renováveis

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
FranciscoCarlosLeiteBrasil_Dissert.pdf2,33 MBAdobe PDFVisualizar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons