Skip navigation

Use este identificador para citar ou linkar para este item: https://repositorio.ufpb.br/jspui/handle/123456789/24928
Registro completo de metadados
Campo DCValorIdioma
dc.creatorDantas, Maria do Socorro Ribeiro-
dc.date.accessioned2022-10-13T16:26:54Z-
dc.date.available2023-08-08-
dc.date.available2022-10-13T16:26:54Z-
dc.date.issued2021-11-30-
dc.identifier.urihttps://repositorio.ufpb.br/jspui/handle/123456789/24928-
dc.description.abstractParabens are esters derived from 4-hydroxybenzoic acid such as methylparaben (MeP), ethylparaben (EtP), propylparaben (PrP), butylparaben (BuP) and benzylparaben (BzP). They are chemical preservatives widely used in cosmetics, pharmaceuticals and foodstuffs, with permitted use in the European Union and also in Brazil, according to legislation of the National Health Surveillance Agency - RDC Resolution No. 162 of September 11, 2001, establishing a maximum concentration allowed for 0,4% individual per ester and 0,8% for mixtures the esters in products of personal hygiene, cosmetics and perfumes. Exposure of people to parabens occurs due to rapid absorption of the skin (cosmetics) as well as in the gastrointestinal tract and blood (medicines and food), endocrine disrupting effect, causing hormonal changes, in addition to being carcinogenic. This work aims to simultaneously determine MeP, EtP; PrP and BuP in artificial sweeteners using glassy carbon electrode by square wave voltammetry associated with second order calibration. The response potential and sensitivity vary with the change in the pH of the medium, greater sensitivity in Britton Robunson buffer (pH = 4.5) range with linear response from 0.78 to 4.48 μmol L-1 LOD and LOQ of 0, 017 μ mol L-1 and 0.0581 μmol L-1 , respectively. Calibration models were constructed for each analyte using split squares with residual bilinearization (U-PLS / RBL) and multivariate curve resolution with alternating squares (MCR-ALS). The models were evaluated using a validation set (16 mixtures) obtained from a Taguchi design, presenting a Relative Error Prediction range ranging from 3.30% to 3.88% and 5.70% to 7.60% , respectively. Finally, the U-PLS/RBL and MCR-ALS calibration models were applied to nine samples of sweeteners, demonstrating a great analytical performance and achieving the second order advantage, with a range of recoveries ranging from 82.6% to 121 % and 83,0% to 123% respectively. Thus, the proposed method proved to be an effective and unprecedented alternative for the simultaneous analysis of parabens in sweeteners.pt_BR
dc.description.provenanceSubmitted by Fernando Augusto Alves Vieira (fernandovieira@biblioteca.ufpb.br) on 2022-10-05T11:22:13Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) MariaDoSocorroRibeiroDantas_Tese.pdf: 3742548 bytes, checksum: 6db1745cbe0cb4bbb2d8bda42d805a85 (MD5)en
dc.description.provenanceApproved for entry into archive by Biblioteca Digital de Teses e Dissertações BDTD (bdtd@biblioteca.ufpb.br) on 2022-10-13T16:26:54Z (GMT) No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) MariaDoSocorroRibeiroDantas_Tese.pdf: 3742548 bytes, checksum: 6db1745cbe0cb4bbb2d8bda42d805a85 (MD5)en
dc.description.provenanceMade available in DSpace on 2022-10-13T16:26:54Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) MariaDoSocorroRibeiroDantas_Tese.pdf: 3742548 bytes, checksum: 6db1745cbe0cb4bbb2d8bda42d805a85 (MD5) Previous issue date: 2021-11-30en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rightsAcesso embargadopt_BR
dc.rightsAttribution-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/*
dc.subjectParabenospt_BR
dc.subjectAdoçantept_BR
dc.subjectEletrodo de carbono vítreopt_BR
dc.subjectVoltametria de onda quadradapt_BR
dc.subjectCalibração de segunda ordempt_BR
dc.subjectParabenspt_BR
dc.subjectSweetenerspt_BR
dc.subjectGlass carbon electrodept_BR
dc.subjectSquare wave voltammetrypt_BR
dc.subjectSecond order calibrationpt_BR
dc.titleDeterminação simultânea de parabenos em adoçantes usando técnicas voltamétricas e calibração de segunda ordempt_BR
dc.typeTesept_BR
dc.contributor.advisor1Araújo, Mário César Ugulino de-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/7281739070942782pt_BR
dc.contributor.advisor-co1Bichinho, Kátia Messias-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/5693184169699400pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6399533374901008pt_BR
dc.description.resumoOs parabenos, tais como: metilparabeno (MeP), etilparabeno (EtP), propilparabeno (PrP), butilparabeno (BuP) e benzilparabeno (BzP), são ésteres derivados do ácido 4-hidroxibenzoico e amplamente utilizado como conservantes químicos em cosméticos, fármacos e alimentos. O uso desses compostos nas matrizes citadas é permitido no Brasil, conforme legislação da Agência Nacional de Vigilância Sanitária – Resolução RDC n° 162, de 11 de setembro de 2001, que estabelece uma concentração máxima permitida de 0,4% individual por éster e 0,8% para misturas de ésteres em produtos de higiene pessoal, cosméticos e perfumes. A exposição de pessoas aos parabenos ocorre devido à rápida absorção dérmica (cosméticos) como também no trato gastrointestinal e sangue (medicamentos e alimentos), apresentando efeito desregulador endócrino, causando alterações hormonais, além de ser carcinogênico. Este trabalho tem como objetivo determinar simultâneamente MeP, EtP; PrP e BuP em adoçantes artificiais usando eletrodo de carbono vítreo por voltametria de onda quadrada associada à calibração de segunda ordem. O potencial de resposta e a sensibilidade variam com a mudança de pH do meio, apresentando maior sensibilidade usando o tampão Britton Robinson (pH = 4,5) com faixa linear de resposta de 0,78 a 4,48 μmol L-1 , LOD e LOQ de 0,017 μ mol L-1 e 0,0581 μmol L 1 , respectivamente. Modelos de calibração foram construídos para cada analito usando mínimos quadrados parciais desdobrados com bilinearização residual (U-PLS/RBL) e resolução de curvas multivariadas com mínimos quadrados alternados (MCR-ALS). Os modelos foram avaliados usando um conjunto de validação (16 misturas) obtido a partir de um planejamento Taguchi, apresentando uma faixa de Erro Relativo de Predição variando de 3,3% a 3,9% e 5,70% a 7,60%, respectivamente. Finalmente, os modelos de calibração U-PLS/RBL e MCR ALS foram aplicados em nove amostras de adoçantes, demonstrando um ótimo desempenho analítico e alcançando a vantagem de segunda ordem, com faixa de recuperações variando de 82,6% a 121% e 83,0% a 123%, respectivamente. Dessa forma, o método proposto mostrou ser uma alternativa eficaz e inédita para a análise simultânea de parabenos em adoçantes.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentQuímicapt_BR
dc.publisher.programPrograma de Pós-Graduação em Químicapt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICApt_BR
Aparece nas coleções:Centro de Ciências Exatas e da Natureza (CCEN) - Programa de Pós-Graduação em Química

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
MariaDoSocorroRibeiroDantas_Tese.pdf3,65 MBAdobe PDFVisualizar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons