Skip navigation

Use este identificador para citar ou linkar para este item: https://repositorio.ufpb.br/jspui/handle/123456789/39321
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSoares, Fernanda Silva-
dc.date.accessioned2026-09-29T10:30:41Z-
dc.date.available2023-05-04-
dc.date.available2026-09-29T10:30:41Z-
dc.date.issued2022-08-29-
dc.identifier.urihttps://repositorio.ufpb.br/jspui/handle/123456789/39321-
dc.description.abstractThe diuron herbicide is one of the most used pesticides in Brazil for weed control and has caused great environmental and public health concerns, due to its toxicity and carcinogenic potential. The use of pesticides on a large scale can contaminate water, which can cause acute problems and effects for the human body, through its exposure. Thus, the development of methods to determine substances in water (or different methods) quickly, effectively and at low cost have been used. As electroanalytical techniques, they can be presented as alternatives of chromatographic practicality, due to their low acquisition cost, high sensitivity, speed, and practical miniaturization capacity for chromatographic analysis. Therefore, in this work, the glassy carbon electrode (GCE) was subjected to electrochemical studies using the techniques of cyclic voltammetry (CV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV). With the voltammetric studies carried out, a peak of diuron oxidation was observed at approximately +1.15 V, through an irreversible process, with pH 2.2 in the Britton-Robson buffer being the most sensitive means of analysis, with a transport of mass governed by diffusion. Among the techniques for quantitative studies, SWV was more sensitive when compared to DPV, so the experimental parameters chosen were frequency 25 s-1, pulse amplitude 70 mV and potential increment of 10 mV. The analytical curve was constructed in a linear range of 38,46 – 115,04 nmol L-1, obtaining a detection and quantification limit of 0.200 nmol L-1 and 0.606 nmol L-1, respectively. The proposed method was successfully applied to the waters of João Pessoa and the metropolitan region, and an amount of diuron (44.02 nmol L-1) was detected in one of them (sample P6). The recovery test applied to all eight analyzed water samples showed good recovery values ranging from 87.99% and 108.02%, which demonstrates the efficiency of the method developed and provides greater reliability in the results achieved. Thus, studies to determine diuron in tap and river water have shown to be promising, enabling the use of the developed method.pt_BR
dc.description.provenanceSubmitted by Fernando Augusto Alves Vieira (fernandovieira@biblioteca.ufpb.br) on 2026-09-29T10:30:41Z No. of bitstreams: 4 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) FernandaSilvaSoares_Dissert_Com_Tarjamento.pdf: 3431384 bytes, checksum: 8d60efa2fc65e5e8abc69fb114fa36f3 (MD5) FernandaSilvaSoares_Dissert_Ficha_SIGAA.pdf: 2101 bytes, checksum: 7b8737b41bda59f5aef95f0d62af1a1b (MD5) FernandaSilvaSoares_Dissert_Sem_Tarjamento.pdf: 2203931 bytes, checksum: 21bd370352ff222b76ac2ad7660ecf72 (MD5)en
dc.description.provenanceMade available in DSpace on 2026-09-29T10:30:41Z (GMT). No. of bitstreams: 4 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) FernandaSilvaSoares_Dissert_Com_Tarjamento.pdf: 3431384 bytes, checksum: 8d60efa2fc65e5e8abc69fb114fa36f3 (MD5) FernandaSilvaSoares_Dissert_Ficha_SIGAA.pdf: 2101 bytes, checksum: 7b8737b41bda59f5aef95f0d62af1a1b (MD5) FernandaSilvaSoares_Dissert_Sem_Tarjamento.pdf: 2203931 bytes, checksum: 21bd370352ff222b76ac2ad7660ecf72 (MD5) Previous issue date: 2022-08-29en
dc.description.sponsorshipConselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPqpt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rightsAcesso abertopt_BR
dc.rightsAttribution-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/*
dc.subjectDiuronpt_BR
dc.subjectÁguapt_BR
dc.subjectEletrodo de carbono vítreopt_BR
dc.subjectVoltametria de onda quadradapt_BR
dc.subjectWaterpt_BR
dc.subjectGlassy carbon electrodept_BR
dc.subjectSquare wave voltammetrypt_BR
dc.titleAnálise voltamétrica de diuron em águas usando eletrodo de carbono vítreopt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Araújo, Mário César Ugulino de-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/7281739070942782pt_BR
dc.contributor.advisor-co1Silva, Amanda Cecília da-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/9642562555290396pt_BR
dc.contributor.referee1Ribeiro, Williame Farias-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/6179867510942876pt_BR
dc.contributor.referee2Lemos, Sherlan Guimarães-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/1602277501575415pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/6008502490620439pt_BR
dc.description.resumoO herbicida diuron é um dos pesticidas mais utilizados no Brasil para o controle de ervas daninha e tem causado grandes preocupações ambientais e de saúde pública, devido a sua toxicidade e potencial carcinogênico. A utilização dos pesticidas em larga escala pode contaminar as águas, podendo causar problemas agudos e crônicos para o organismo humano, através da sua exposição. Assim, o desenvolvimento de métodos analíticos para determinar essa substância em água (ou diferentes matrizes) de formarápida, eficaz e com baixo custo, têm sido de grande relevância. As técnicas eletroanalíticas apresentam-se como alternativa às cromatográficas, por apresentarem baixo custo de aquisição, alta sensibilidade, rapidez e praticidade. Dessa maneira, neste trabalho, o eletrodo de carbono vítreo (ECV) foi submetido a estudos eletroquímicos utilizando as técnicas de voltametria cíclica (VC), voltametria de onda quadrada (VOQ) e voltametria de pulso diferencial (VPD). Com os estudos voltametricos realizados, foi observado um pico de oxidação do diuron em aproximadamente +1,15 V, através de um processo irreversível, sendo o pH 2,2 no tampão Britton-Robson o mais sensível de análise, com um transporte de massa governado por difusão. Entre as técnicas para os estudos quantitativos, a VOQ se mostrou mais sensível quando comparada com a VPD, sendo essa a escolhida para os estudos quantitativos, assim, os parâmetros experimentais escolhidos foram frequência 25 s-1, amplitude de pulso 70 mV e incremento de potencial de 10 mV. A curva analítica foi construída em uma faixa linear de 38,46 – 115,04 nmol L-1, sendo obtido um limite de detecção e quantificação de 0,200 nmol L-1 e 0,606 nmol L-1, respectivamente. O método proposto foi aplicado com sucesso nas águas de João Pessoa e Região metropolitana, sendo detectado uma quantidade de diuron (44,02 nmol L-1) em uma delas (amostra P6). O teste de recuperação aplicado em todas as oito amostras de água para consumo humano analisadas, apresentaram bons valores de recuperação variando de 87,99 % - 108,02%, o que demonstra a eficiência do método desenvolvido e proporciona uma maior confiabilidade nos resultados alcançados. Desse modo, os estudos para determinação de diuron em água, de torneira e de rio, se mostraram promissores, viabilizando a utilização do método desenvolvido.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentQuímicapt_BR
dc.publisher.programPrograma de Pós-Graduação em Químicapt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICApt_BR
dc.publisher.programcode24001015030P4pt_BR
Aparece nas coleções:Centro de Ciências Exatas e da Natureza (CCEN) - Programa de Pós-Graduação em Química



Este item está licenciada sob uma Licença Creative Commons Creative Commons