Skip navigation

Use este identificador para citar ou linkar para este item: https://repositorio.ufpb.br/jspui/handle/123456789/39942
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSouza, Gracielle Ferreira de-
dc.date.accessioned2026-11-26T18:04:36Z-
dc.date.available2026-06-17-
dc.date.available2026-11-26T18:04:36Z-
dc.date.issued2026-02-10-
dc.identifier.urihttps://repositorio.ufpb.br/jspui/handle/123456789/39942-
dc.description.abstractThe increasing presence of herbicides in surface and groundwater, including public water supply sources, has raised concerns due to their persistence, toxicity, and resistance to conventional treatment processes. Considering the limited biodegradability of these compounds and the high cost of Advanced Oxidation Processes (AOPs), there is a need to explore alternatives that enable their application in a more economically viable manner for the treatment of such contaminants. In this context, this study aimed to compare homogeneous AOP systems for the photodegradation of the herbicides diuron (DRN), 2,4- dichlorophenoxyacetic acid (2,4-D), and 2,4-dichlorophenol (2,4-DCP) in a low-cost photolytic reactor, evaluating efficiency, reaction kinetics, and cost. In the initial stage, the Fenton (Fe²⁺/H₂O₂), photo-Fenton (Fe²⁺/H₂O₂/UV-C), UV-C peroxidation (H₂O₂/UV-C), direct photolysis (UV-C), and homogeneous oxidation (H₂O₂) processes were evaluated, with the H₂O₂/UV-C system selected for the subsequent stage due to its highest efficiency. In the second stage, the H₂O₂/UV-C, UV-C ozonation (O₃/UV-C), and NaOCl/UV-C systems were optimized using a Central Composite Rotatable Design (CCRD), combined with Pareto analysis and Response Surface Methodology (RSM), considering oxidant (or herbicide) concentration and initial pH. After determining the optimized conditions of the most efficient AOP for each herbicide, the reactor construction costs and operational costs per m³ of contaminated water were estimated, considering energy consumption (EEO) and reagent usage. DRN showed higher photochemical sensitivity, whereas 2,4-D and 2,4-DCP exhibited low response to UV-C radiation. In the H₂O₂/UV-C process, acidic conditions enhanced DRN photodegradation efficiency, while higher H₂O₂ concentrations favored the photodegradation of 2,4-D and 2,4-DCP. In the O₃/UV-C system, the operational variables did not show statistically significant effects on the photodegradation of the three herbicides. Similarly, in the NaOCl/UV-C process, no influence was observed for DRN and 2,4-DCP, whereas higher NaOCl concentrations had a negative effect on 2,4-D photodegradation. The NaOCl/UV-C process (NaOCl=60 mg L-1; pH=5; herbicida 5 mg L-1) was the most viable for DRN, achieving 84,66% photodegradation in 30 minutes, a high second-order reaction rate constant (K₂=176,49 L mol-1 min-1), and low operational cost (R$ 7,01 m-3). For 2,4-D and 2,4-DCP, the O₃/UV-C system (O3=6 mg L-1; herbicida=7,83 mg L-1; pH 9) showed the highest efficiencies (92,56% and 90,00% in 20 minutes, respectively), albeit with a higher cost (R$ 1.557,00 m-3). It was concluded that AOPs based on commercially available oxidants, such as NaOCl and H₂O₂, combined with a low-cost photolytic reactor, constitute an effective and economically viable alternative for the photodegradation of herbicides and the mitigation of environmental impacts. The O₃/UV-C process stood out for its high efficiency and shorter reaction time, although with higher operational costs.pt_BR
dc.description.provenanceSubmitted by Jackson R. L. A. Nunes (jackson@biblioteca.ufpb.br) on 2026-11-26T18:04:36Z No. of bitstreams: 1 GracielleFerreiraDeSouza_Tese.pdf: 5873523 bytes, checksum: 186c26f81d7673ff71b4bca8aab97fce (MD5)en
dc.description.provenanceMade available in DSpace on 2026-11-26T18:04:36Z (GMT). No. of bitstreams: 1 GracielleFerreiraDeSouza_Tese.pdf: 5873523 bytes, checksum: 186c26f81d7673ff71b4bca8aab97fce (MD5) Previous issue date: 2026-02-10en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rights.urihttps://creativecommons.org/licenses/by-nd/4.0/pt_BR
dc.subjectReator fotolíticopt_BR
dc.subjectProcessos oxidativos avançadospt_BR
dc.subjectFotodegradaçãopt_BR
dc.subjectCinética de reaçãopt_BR
dc.subjectCusto operacionalpt_BR
dc.subjectPhotodegradation efficiencyen
dc.subjectResponse surface methodologyen
dc.subjectReaction kineticsen
dc.subjectWastewater treatmenten
dc.titleComparação entre sistemas homogêneos de Processos Oxidativos Avançados aplicados para a degradação de herbicidas: eficiência, cinética e custo operacionalpt_BR
dc.typeTesept_BR
dc.contributor.advisor1Madeira, Vivian Stumpf-
dc.contributor.advisor1Latteshttps://busca-cv-lattes.cnpq.br/curriculo/9099676593150810pt_BR
dc.contributor.referee1Rocha, Elisângela Maria Rodrigues-
dc.contributor.referee1Latteshttps://busca-cv-lattes.cnpq.br/curriculo/4605777405185416pt_BR
dc.contributor.referee2Athayde Junior, Gilson Barbosa-
dc.contributor.referee2Latteshttps://busca-cv-lattes.cnpq.br/curriculo/8220830326280125pt_BR
dc.contributor.referee3Motta Sobrinho, Maurício Alves da-
dc.contributor.referee3Latteshttps://busca-cv-lattes.cnpq.br/curriculo/3644581240048018pt_BR
dc.contributor.referee4Pokrywiecki, Ticiane Sauer-
dc.contributor.referee4Latteshttps://busca-cv-lattes.cnpq.br/curriculo/6567263273805853pt_BR
dc.creator.Latteshttps://busca-cv-lattes.cnpq.br/curriculo/0414869464759003pt_BR
dc.description.resumoA crescente presença de herbicidas em águas superficiais e subterrâneas, incluindo mananciais de abastecimento público, tem gerado preocupação devido à sua persistência, toxicidade e resistência aos tratamentos convencionais. Considerando a limitada biodegradabilidade desses compostos e o elevado custo dos Processos Oxidativos Avançados (POAs), torna-se necessária a busca por alternativas que possibilitem sua aplicação de maneira mais economicamente viável no tratamento desses contaminantes. Nessa perpectiva, este estudo teve como objetivo comparar sistemas homogêneos de POAs para a fotodegradação dos herbicidas diuron (DRN), ácido 2,4-diclorofenoxiacético (2,4-D) e 2,4-diclorofenol (2,4-DCP) em um reator fotolítico desenvolvido com material de baixo custo, avaliando eficiência, cinética de reação e custo. Na etapa inicial, foram avaliados os processos Fenton (Fe²⁺/H₂O₂), foto-Fenton (Fe²⁺/H₂O₂/UV-C), Peroxidação com radiação UV-C (H₂O₂/UV-C), fotólise direta (UV-C) e oxidação homogênea (H₂O₂), sendo o sistema H₂O₂/UV-C selecionado para a etapa seguinte por ter apresentado a maior eficiência. Na segunda etapa, os sistemas H₂O₂/UV-C, ozonização com UV-C (O₃/UV-C) e NaOCl/UV-C foram otimizados por meio do planejamento fatorial do tipo Delineamento Composto Central Rotacional (DCCR), aliado à análise de Pareto e à Metodologia de Superfície de Resposta (MSR), considerando a concentração do agente oxidante (ou do herbicida) e o pH inicial. Após a definição das condições otimizadas do POA mais eficiente para cada herbicida, foram estimados os custos de implantação do reator e os custos operacionais do tratamento por m³ de água contaminada, considerando o consumo energético (EEO) e de reagentes. O DRN apresentou maior sensibilidade fotoquímica, enquanto o 2,4-D e o 2,4- DCP mostraram baixa resposta à radiação UV-C. No processo H₂O₂/UV-C, a condição ácida promoveu melhor eficiência de fotodegradação do DRN, enquanto maiores concentrações de H₂O₂ favoreceram a fotodegradação do 2,4-D e 2,4-DCP. No sistema O₃/UV-C, as variáveis operacionais não apresentaram significância estatística na fotodegradação dos três herbicidas. No NaOCl/UV-C, também não houve influência para o DRN e o 2,4-DCP, enquanto concentrações elevadas de NaOCl apresentaram efeito negativo na fotodegradação do 2,4-D. O processo NaOCl/UV-C (NaOCl=60 mg L-1; pH=5; herbicida 5 mg L-1) foi o mais viável para o DRN, alcançando 84,66% de fotodegradação em 30 minutos, elevada constante cinética de reação (K₂=176,49 L mol-1 min-1) e baixo custo operacional (R$ 7,01 m-3). Para o 2,4-D e o 2,4-DCP, o sistema O₃/UV-C (O3=6 mg L-1; herbicida=7,83 mg L-1; pH 9) apresentou as maiores eficiências (92,56% e 90,00% em 20 minutos), porém com custo superior (R$ 1.557,00 m-3). Constatou-se que a aplicação de POAs baseados em agentes oxidantes comercialmente disponíveis, como NaOCl e H₂O₂, associada ao uso de um reator fotolítico desenvolvido com materiais acessíveis, constitui uma alternativa eficaz e economicamente viável para a fotodegradação de herbicidas e a mitigação de impactos ambientais. O processo O₃/UV-C destacou-se pela elevada eficiência e menor tempo de reação, porém com custos operacionais mais elevados.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEngenharia Civil e Ambientalpt_BR
dc.publisher.programPrograma de Pós-Graduação em Engenharia Civil e Ambientalpt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA CIVILpt_BR
dc.publisher.programcode24001015040P0pt_BR
Aparece nas coleções:Centro de Tecnologia (CT) - Programa de Pós-Graduação em Engenharia Civil e Ambiental

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
GracielleFerreiraDeSouza_Tese.pdf5,74 MBAdobe PDFVisualizar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons