dc.description.abstractIn 2018, estimates that about 310 TWh were destined to supply irregular connections and measurements in Brazil, approximately R$ 9 billion losses for distributors. The concessionaire of this study faces challenges to detect fraud, mainly due to the volume of data and the limitation on finding patterns without a structured tool. Considering this scenario, the development of an automated methodology is proposed to detect fraud in low voltage customers, without telemetry, using artificial intelligence tools. Information was extracted from the company's database, attributes were implemented, the main variables were selected and then the models were evaluated. The main variable proposed compares the average consumption of the unit with the closest geographic neighbors with similar size characteristics. Variables are also proposed aiming to detect the moment of a reduction in the energy consumption, as well as its value. The most common Machine Learning techniques were tested and four models were proposed: Support Vector Machine was used for consumers with an indication of possible fraud; for residential units without this indication, Gradient Boosting was used; for rural units, Random Forest was used; for the other classes, a Multilayer Perceptron Neural Network was used. The models were qualified based on a new metric, proposed as an alternative to the usual evaluation metrics, which computes the percentage of the energy benefit theoretically recovered by the model in relation to all the energy that could have been recovered. In theoretical tests, it was possible to obtain an accuracy of 39.4%, surpassing 19.5% the current methodology of the company, with 69.8% greater recall. The energy benefit metric also shows that the proposed methodology was able to recover 59.5% of the total amount of energy available, 153.2% higher than the company's current model. New research involves the application of the proposed methodology to the company's base for the classification of the consumers and inspections will be sent to verify the results.pt_BR
dc.description.provenanceSubmitted by Gracilene Figueiredo (gracilene.barbosa@biblioteca.ufpb.br) on 2020-12-11T14:02:04Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) FernandaRodriguesPaulo_Dissert.pdf: 3402368 bytes, checksum: f785b9b82de44bef7291462991f0cd8c (MD5)en
dc.description.provenanceApproved for entry into archive by Biblioteca Digital de Teses e Dissertações BDTD (bdtd@biblioteca.ufpb.br) on 2020-12-14T00:24:19Z (GMT) No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) FernandaRodriguesPaulo_Dissert.pdf: 3402368 bytes, checksum: f785b9b82de44bef7291462991f0cd8c (MD5)en
dc.description.provenanceMade available in DSpace on 2020-12-14T00:24:19Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) FernandaRodriguesPaulo_Dissert.pdf: 3402368 bytes, checksum: f785b9b82de44bef7291462991f0cd8c (MD5) Previous issue date: 2020-07-31en
dc.description.sponsorshipNenhumapt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rightsAcesso abertopt_BR
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/*
dc.subjectPerdas comerciaispt_BR
dc.subjectPerdas não técnicaspt_BR
dc.subjectFraude de energiapt_BR
dc.subjectClassificação de padrõespt_BR
dc.subjectAprendizado de máquinapt_BR
dc.subjectInteligência Artificialpt_BR
dc.subjectDetecção de fraudept_BR
dc.subjectRecuperação de consumopt_BR
dc.subjectCommercial lossespt_BR
dc.subjectNon-technical lossespt_BR
dc.subjectEnergy fraudpt_BR
dc.subjectPattern classificationpt_BR
dc.subjectMachine learningpt_BR
dc.subjectArtificial intelligencept_BR
dc.subjectFraud detectionpt_BR
dc.subjectConsumption recoverypt_BR
dc.titleDetecção de fraude em unidades consumidoras não telemedidas com uso de técnicas de aprendizado de máquinapt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Villanueva, Juan Moises Mauricio-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1446817462218646pt_BR
dc.contributor.advisor-co1Braz, Helon David de Macêdo-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/4756997631027455pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/1604040436473143pt_BR
dc.description.resumoEstima-se que em 2018 cerca de 310 TWh foram destinados a alimentação de ligações e medições irregulares no Brasil, aproximadamente R$ 9 bilhões de prejuízo para as distribuidoras. Para a concessionária de estudo, são observadas dificuldades para a detecção de fraudes, devido, principalmente, ao volume de dados e a limitação de encontrar padrões sem uma ferramenta estruturada. Considerando esse cenário, propõe-se o desenvolvimento de uma metodologia automatizada para detecção de fraude em clientes da baixa tensão, não telemedidos, com a utilização de ferramentas de inteligência artificial. Foram extraídas informações do banco de dados da empresa, gerados atributos, selecionadas as principais variáveis e, então, avaliados os modelos. A principal variável proposta compara a média de consumo da unidade com os vizinhos geográficos mais próximos com características de porte semelhantes. Também são propostas variáveis que detectam o momento que houve uma redução de consumo, bem como o percentual, através de cálculos estatísticos. As técnicas de aprendizado de máquina mais utilizadas na literatura foram testadas e, no fim, quatro modelos foram propostos: Support Vector Machine para unidades com indicação de suspeita de fraude; Gradiente Boosting para unidades residenciais sem suspeita de fraude; Random Forest para unidades rurais; Rede Neural Perceptron Multicamadas para as demais classes de consumo. Os modelos foram qualificados e as técnicas selecionadas a partir de um novo indicador, proposto como alternativa as métricas usuais de avaliação, que computa o percentual do benefício de energia teoricamente recuperada pelo modelo em relação a toda a energia que poderia ter sido recuperada. Em testes teóricos, foi possível obter uma efetividade de 39,4%, ultrapassando 19,5% a metodologia atual da empresa, com uma cobertura 69,8% maior. O indicador de benefício evidencia também que o método apresentado foi capaz de recuperar 59,5% de todo montante de energia disponível, 153,2% superior ao modelo da empresa. Novas pesquisas envolvem a aplicação da metodologia proposta a base da empresa para classificação das unidades e envio de inspeções para verificar o resultado do trabalho em campo.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEngenharia Elétricapt_BR
dc.publisher.programPrograma de Pós-Graduação em Engenharia Elétricapt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA ELETRICApt_BR
Aparece nas coleções:Centro de Energias Alternativas e Renováveis (CEAR) - Programa de Pós-Graduação em Engenharia Elétrica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
FernandaRodriguesPaulo_Dissert.pdf3,32 MBAdobe PDFVisualizar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons