Skip navigation

Use este identificador para citar ou linkar para este item: https://repositorio.ufpb.br/jspui/handle/123456789/24199
Registro completo de metadados
Campo DCValorIdioma
dc.creatorFreitas, Maria Silva-
dc.date.accessioned2022-08-11T16:59:50Z-
dc.date.available2022-06-28-
dc.date.available2022-08-11T16:59:50Z-
dc.date.issued2022-03-31-
dc.identifier.urihttps://repositorio.ufpb.br/jspui/handle/123456789/24199-
dc.description.abstractThe present work studied and determined the aging factor for concrete mixtures containing pozzolanic additions, considering measurements of electrical resistivity and diffusion of chloride ions in a laboratory environment. For this pourpose, cylindrical specimens with 100 mm diameter and 200 mm high were casted for eight different mixtures, composed of Portland cement of initial high strength, fly ash, metakaolin and silica fume. After the curing period, the samples were submitted to pure diffusion tests, following the recommendations of NT Build 443; surface electrical resistivity, by Wenner method; axial compressive strength and total water absorption by immersion. The results show that the age factor varied in a range of 0.100 to 0.999. For the age factor obtained from diffusion data, age factor "n", this interval was divided into three: 0.100 – 0.450, concrete without addition and concrete with the addition of silica fume; 0.300 - 0.600, concrete with the addition of metakaolin; 0.600 - 0.900, concrete with added fly ash. For the factor "q", an ageing factor obtained by readings of surface electrical resistivity, this interval ranged from: 0 - 0.420, for concrete without addition, concrete with the addition of silica fume and concrete with the addition of metakaolin, 0.620 - 0.999 for concrete with the addition of fly ash.pt_BR
dc.description.provenanceSubmitted by Fernando Augusto Alves Vieira (fernandovieira@biblioteca.ufpb.br) on 2022-08-04T11:06:58Z No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) MariaSilvaFreitas_Dissert.pdf: 2686421 bytes, checksum: c12c22586f7e1fea87512eae5ad6c19f (MD5)en
dc.description.provenanceApproved for entry into archive by Biblioteca Digital de Teses e Dissertações BDTD (bdtd@biblioteca.ufpb.br) on 2022-08-11T16:59:50Z (GMT) No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) MariaSilvaFreitas_Dissert.pdf: 2686421 bytes, checksum: c12c22586f7e1fea87512eae5ad6c19f (MD5)en
dc.description.provenanceMade available in DSpace on 2022-08-11T16:59:50Z (GMT). No. of bitstreams: 2 license_rdf: 805 bytes, checksum: c4c98de35c20c53220c07884f4def27c (MD5) MariaSilvaFreitas_Dissert.pdf: 2686421 bytes, checksum: c12c22586f7e1fea87512eae5ad6c19f (MD5) Previous issue date: 2022-03-31en
dc.description.sponsorshipNenhumapt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Paraíbapt_BR
dc.rightsAcesso abertopt_BR
dc.rightsAttribution-NoDerivs 3.0 Brazil*
dc.rights.urihttp://creativecommons.org/licenses/by-nd/3.0/br/*
dc.subjectFator de idadept_BR
dc.subjectCoeficiente de difusãopt_BR
dc.subjectResistividade elétrica superficialpt_BR
dc.subjectAdições mineraispt_BR
dc.subjectAging factorpt_BR
dc.subjectDiffusionpt_BR
dc.subjectSurface electrical resistivitypt_BR
dc.subjectMineral additionspt_BR
dc.titleAvaliação do fator de idade em concretos com distintas composiçõespt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor1Meira, Gibson Rocha-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4589258287572417pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/2613266978844530pt_BR
dc.description.resumoO presente trabalho estudou e determinou o fator de idade para misturas de concretos contendo adições pozolânicas, considerando medidas de resistividade elétrica e difusão de íons cloretos, em ambiente de laboratório. Para tal, foram moldados corpos de prova cilíndricos com 100 mm de diâmetro e 200 mm de altura para oito misturas diferentes, compostas por cimento Portland de alta resistência inicial, cinza volante, metacaulim e sílica ativa. Após o período de cura, as amostras foram submetidas aos ensaios de difusão pura, seguindo as recomendações da NT Build 443; resistividade elétrica superficial, pelo método de Wenner; resistência à compressão axial e absorção total de água por imersão. Os resultados mostraram que o fator de idade variou em uma faixa de 0,100 a 0,999. Para o fator de idade obtido a partir de dados de difusão, fator de idade “n”, esse intervalo foi dividido em três: 0,100 – 0,450, concreto sem adição e concreto com adição de sílica ativa; 0,300 – 0,600, concreto com adição de metacaulim; 0,600 – 0,900, concreto com adição de cinza volante. Já para o fator “q”, fator de idade obtido por leituras de resistividade elétrica superficial, esse intervalo variou de: 0 - 0,420, para concreto sem adição, concreto com adição de sílica ativa e concreto com adição de metacaulim e 0,620 – 0,999 para concreto com adição de cinza volante.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEngenharia Civil e Ambientalpt_BR
dc.publisher.programPrograma de Pós-Graduação em Engenharia Civil e Ambientalpt_BR
dc.publisher.initialsUFPBpt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA CIVILpt_BR
Aparece nas coleções:Centro de Tecnologia (CT) - Programa de Pós-Graduação em Engenharia Civil e Ambiental

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
MariaSilvaFreitas_Dissert.pdf2,62 MBAdobe PDFVisualizar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons