Please use this identifier to cite or link to this item: https://repositorio.ufpb.br/jspui/handle/tede/7057
metadata.dc.type: Dissertação
Title: Um luminômetro Fluxo-Batelada para Determinação de Vitamina B12 em Medicamentos.
Other Titles: A Flow-Batch Luminometer for Determination of Vitamin B12 in Pharmaceutical Formulations.
metadata.dc.creator: Andrade, Renato Allan Navarro
metadata.dc.contributor.advisor1: Araújo, Mário César Ugulino de
metadata.dc.description.resumo: Neste trabalho foi desenvolvido um luminômetro para análise por quimiluminescência, acoplado a um sistema automático de análise em fluxo-batelada. O desempenho do instrumento desenvolvido foi avaliado por meio da determinação de vitamina B12 em medicamentos. O princípio químico do sistema baseia-se no efeito catalítico do íon cobalto (II) sobre a oxidação do luminol pelo peróxido de hidrogênio em meio alcalino cujo produto da reação emite radiação eletromagnética na região visível (mais precisamente em 425 nm). O sistema de detecção do instrumento desenvolvido consiste de um fotodiodo de silício e de um módulo para amplificação dos sinais analíticos. O modelo de calibração univariado foi validado por meio da Análise de Variância (ANOVA) e usado posteriormente na quantificação de vitamina B12 em amostras reais. Os limites de detecção e quantificação obtidos foram 0,11 e 0,36 μg L-1 de vitamina B12. A frequência analítica foi estimada em 90 amostras h-1. A exatidão do instrumento proposto foi atestada por meio de testes de recuperação cujas taxas obtidas foram entre 98 e 102%. O instrumento proposto forneceu resultados com precisão satisfatória, como revelado pelo baixo valor de desvio padrão conjunto. Tais resultados obtidos demonstram que é possível quantificar vitamina B12 utilizando um método simples, econômico, robusto e que produz baixa quantidade de resíduos para o meio ambiente.
Abstract: In this work was developed a luminometer for analysis by chemiluminescence, coupled to a flow-batch analysis automatic system. The performance of the developed instrument was evaluated by means of the determination of vitamin B12 in pharmaceutical formulations. The chemical principle is based on the catalytic effect of cobalt (II) ion over luminol oxidation by hydrogen peroxide in alkaline medium whose reaction product emits electromagnetic radiation in visible region (more precisely at 425 nm). The detection system of the developed instrument consisted of a silicon photodiode and a module for amplification of analytical signals. The univariate calibration model was validated by means of Analysis of Variance (ANOVA) and used later in the quantification of vitamin B12 in real samples. The limits of detection and quantification obtained were 0.11 and 0.36 μg L-1 of vitamin B12. The analytical frequency was estimated in 90 samples h-1. The accuracy of the proposed instrument was attested by means of recovery tests whose obtained recovery rates were between 98 and 102%. The proposed instrument yielded results with satisfactory precision, as revealed by low value of overall standard deviation. Such results demonstrated that is possible to quantify vitamin B12 employing a simple, economic and robust method which generate low amount of waste to the environment.
Keywords: Luminômetro Fluxo-Batelada
Quimiluminescência
Vitamina B12
Flow-Batch Luminometer
Chemiluminescence
Vitamin B12
metadata.dc.subject.cnpq: CIENCIAS EXATAS E DA TERRA::QUIMICA
metadata.dc.language: por
metadata.dc.publisher.country: BR
Publisher: Universidade Federal da Paraí­ba
metadata.dc.publisher.initials: UFPB
metadata.dc.publisher.department: Química
metadata.dc.publisher.program: Programa de Pós-Graduação em Química
Citation: ANDRADE, Renato Allan Navarro. Um luminômetro fluxo-batelada para determinação de Vitamina B12 em medicamentos.. 2011. 112 f. Dissertação (Mestrado em Química) - Universidade Federal da Paraí­ba, João Pessoa, 2011.
metadata.dc.rights: Acesso Aberto
URI: https://repositorio.ufpb.br/jspui/handle/tede/7057
Issue Date: 11-Nov-2011
Appears in Collections:Centro de Ciências Exatas e da Natureza (CCEN) - Programa de Pós-Graduação em Química

Files in This Item:
File Description SizeFormat 
arquivototal.pdf3.26 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.