| Resumo: | A presente tese tem como objetivo o projeto de um controlador adaptativo, para o modelamento e controle em tempo real de um sistema de bombeamento de água por meio do uso simultâneo de válvulas de controle e conversor de frequência utilizado no acionamento de um conjunto motor-bomba, visando reduzir o consumo de água e energia elétrica. Foi desenvolvido um protótipo do sistema de bombeamento de água composto de dois ramais, com o intuito de modelar e identificar parametricamente o conjunto motor-bomba assim como, projetar e implementar controladores adaptativos de Variância Mínima Generalizados (GMV) auto ajustáveis. O controlador atuou na determinação da velocidade de rotação do motor e no ângulo de abertura da válvula de controle. A metodologia consistiu em um estudo teórico e experimental considerando-se que os ramais operam de forma acoplada. Um estudo foi realizado objetivando-se definir a estrutura de modelo para a bancada experimental - números de polos, zeros e de atrasos. Uma vez conhecida e validada a estrutura de modelo, foi obtido o modelo matemático representativo da bancada experimental cujos parâmetros são estimados em tempo real pelo método dos mínimos quadrados recursivo (MQR), em função de entradas impostas ao conversor de frequência e nas válvulas, como também de saídas nos ramais considerando que o sistema é acoplado. Os controladores adaptativos (GMV) auto ajustáveis foram projetados e implementados visando o controle da pressão nos ramais, utilizando no cálculo da lei de controle os parâmetros identificados a cada instante de amostragem, considerando-os como dois sistemas MIMO (multiple-input multiple-output). Os resultados são apresentados para o sistema operando na forma desacoplada e acoplada, sob a ação do controlador projetado para vários valores de referência. |
| Abstract: | This thesis aims at the design of an Adaptive controller for the modeling and real-time control of a water pumping system through the simultaneous use of control valves and frequency converter is used for the drive of a pump motor set, aiming to reduce the consumption of water and electricity. We developed a prototype of the water pumping system composed of two branches, aiming to model and identify the motor-pump set Parametrically as well as design and implement adaptive auto adjustable Generalized Minimum variance controllers (GMV). The controller operates in the determination of engine speed and the aperture angle of the control valve. The methodology consisted of a theoretical and experimental study considering the branches operate so disengaged. A study was carried out in order to define the structure of the model for the experimental bench-numbers of Poles, zeros and delays. Once known and validated the model structure, was retrieved from the mathematical model trial countertop representative whose parameters are estimated in real time by the method of recursive least squares (RLS), on the basis of entries imposed on the frequency converter and valves, as well as extensions output whereas the system is engaged. Adaptive controllers (GMV) auto adjustable have been designed and implemented for the control of pressure in extensions using the calculation of control law the parameters identified every instant of sampling, considering them as two systems MIMO (multiple-input multipleoutput). The results are presented to the operating system as uncoupled and coupled, under the action of the controller designed for various reference values. |
| Palavras-chave: | Bombeamento Pumping Identificação de sistema Controle Adaptativo Adaptive Control System Identification |
| CNPq: | ENGENHARIAS::ENGENHARIA MECANICA |
| Idioma: | por |
| País: | Brasil |
| Editor: | Universidade Federal da Paraíba |
| Sigla da Instituição: | UFPB |
| Departamento: | Engenharia Mecânica |
| Programa: | Programa de Pós-Graduação em Engenharia Mecânica |
| Citação: | SILVA, Magno José Gomes da. Controle adaptativo aplicado a um sistema de bombeamento de água visando a redução das perdas de energia elétrica e água. 2014. 144f. Tese (Doutorado em Engenharia Mecânica) - Universidade Federal da Paraíba, João Pessoa, 2014. |
| Tipo de Acesso: | Acesso aberto |
| URI: | https://repositorio.ufpb.br/jspui/handle/tede/7585 |
| Data do documento: | 29-Dez-2014 |
| Aparece nas coleções: | Centro de Tecnologia (CT) - Programa de Pós-Graduação em Engenharia Mecânica |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| arquivototal.pdf | Arquivo Total | 2,4 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.